1.Automatic door quality and performance should meet the design requirements.
Test methods: inspection of production licenses, product certification and performance test report.
2. Automatic door variety, type, size, size, opening direction, installation location and anti-corrosion treatment should meet the design requirements.
Inspection methods: observation; ruler inspection; check admission acceptance records and concealed project acceptance records.
3. Automatic doors with mechanical devices, automatic devices or intelligent devices whose mechanical device automatic devices or intelligent devices shall comply with the design requirements and the relevant standards.
Test method: start mechanical device, automatic device or intelligent device, observe.
4. Automatic door installation must be solid. The number of embedded parts, location, embedded way, and the box connection must meet the design requirements.
Inspection methods: observation; Handle inspection; inspection concealed project acceptance records.
5.Automatic door accessories should be complete, the location should be correct, the installation should be strong, the function should meet the requirements and the performance requirements of automatic doors.
Inspection methods: observation; Shouban inspection; check product certification, performance test reports and admission records.
|